Air

Compare Tool

Select up to 3 products

1 - 32 of 74
Sort
View
Show
  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Clean with Eco-Confidence! A new duster from the market leader, the Dust-Off ECO Duster is one of the first to utilize a newly-formulated non-flammable, ultra-low Global Warming Potential (GWP) aerosol propellant. The Dust-Off Eco Duster has been environmentally engineered with the same…

  • Micro Essential

    Hydrion Ammonia Meter Test Paper is designed and calibrated to measure the amount of ammonia in air in parts per million wherever there may be actual or potential ammonia pollution. The color chart has matches at 0-5-10-20-50-100ppm. The Hydrion Ammonia Test Kit is especially useful where…

  • Air sampling cane with funnel at one end to avoid water droplets from collecting at edge and being sucked into manifold train. Bulge above the funnel is for glass wool or similar material to allow for filtering of particulates. Codes -22 & -26 feature a #7 Ace-Thred port for introducing calibration…

  • Schlenk style reaction tube for vacuum and No-Air applications. Available in many capacities, joint sizes and side arm configurations including a glass stopcock, 0-3 inlet valve or a 0-4 Hi-Vac valve.

  • Flexible Non contaminating On/off valve closure Use for gas or liquid sample containment Heat-sealed seams for leak-proof operation Reusable bags made of 2 mil PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of non-corrosive gases.…

  • Ace Glass

    7493 air sampling cane 6.4mm mesh PTFE screen assembly. Only available for our 25mm OD canes. Place the screen within the retaining ring, unfasten the yoke's nut & bolt, pass the now open yoke around the funnel and then tighten the nut and bolt to secure the assembly. The screen is held in place…

  • The HPLC Solvents Breakthrough Indicator is qualitative (yes/no) colorimetric indicator of the end-of-service life of low-flow filters. It is designed to provide real-time indication of the saturation and breakthrough of hplc solvents. HPLC solvents include Acetone, Acetonitrile, Chloroform,…

  • Vacuum adapter with 2mm bore stopcock on side arm.

  • The SAS Super 100 & 180 microbial air samplers are the top choices of the world's leading pharmaceutical and food companies, as well as numerous governments around the world for detection of microbial contamination and air quality testing. Featuring a powerful, high volume air flow of…

  • Aromatic Diisocyanates, TDI & MDI (Polyurethane Chemicals), Hydrazine (MIL-P-87930, H-70), Hydrogen Sulfide and Mercury. Chemteq Area Monitors are direct-read colorimetric indicators that indicate the presence of trace toxic chemicals in air. They are reliable and cost effect means for…

  • Sartorius

    The MD8 series of air samplers are monitoring devices combined with novel filtration systems for the exceptional recovery of airborne microorganisms. MD8 AirScan: (Integrated) Quantitative detection in sterile areas such as clean rooms/RABS, isolators, or blow-fill-seal machines. …

  • Ace Glass

    Unique impinger designed to be more economical when connecting in series eliminates need for connecting tubes.The 12/5 joints are perpendicular and come directly off bottle 180 degree apart. Screw cap on bottle has PTFE liner. Each bottle has one ball and one socket joint. Capacity 25mL. Bottle is…

  • A high velocity impinger (Ref. AGI-30) which passes 12.0 to 13.0L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Dräger

    DrägerTubes® are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. A calibrated 100mL sample of air is drawn through the tube with the Dräger accuro® bellows pump. If the targeted chemical(s) is present the reagent in the…

  • Ace Glass

    Bubbler with either fritted tip or plain orifice stopper. Bottle has 24/40 joint and 10 cm tube below bulge. Stopper has 12/5 outer joint on inlet arm and 12/5 inner on outlet arm. Fritted tip is porosity C (25-50m). Orifice tip is 1.5mm capillary with end tapered. Approximate capacity, with…

  • Cole-Parmer

    Instantly cool electrical components to -65°F (-53.8°C). Dries fast and leaves no residue  Quickly deliver freezing power to hard-to-reach places  Ultra-low global warming potential (GWP)  Nonflammable and ozone safe.

  • Carbon Adsorbers and Filters Change Indicators for Ammonia, Ammonia & Hydrogen Sulfide, Hydrazine and Hydrogen Sulfide. The breakthrough (saturation) indicators are colorimetric indicators that indicate the saturation and exhaustion of carbon adsorbers and filters. The indicators are…

  • Real-time filter breakthrough indicators. You don't have to change your filter in 3 months, 6 months or 9 months, change your filter only when exhausted and saturated using real-time breakthrough indicators. Get the most use of your filters and protect yourself from exposure to toxic chemicals.…

  • Schlenk style flask for vacuum, NO-AIR or gas applications. Can be used for storage or reactions. Top is either a no.15 o-ring or outer standard taper joints. Side arm has either a 0-3 inlet valve or a 2mm or a 4mm glass stopcock.

  • Carbon adsorbers and Filters Change Indicators for Ammonia, Ammonia & Hydrogen Sulfide, Hydrazine and Hydrogen Sulfide. The breakthrough (saturation) indicators are colorimetric indicators that indicate the saturation and exhaustion of carbon adsorbers and filters. The indicators are…

  • Ace Glass

    Glass Manifold with #15 Ace-Thred at either end To allow switching 5853 vacuum connection to left or right side. Supplied with three or five, 4mm straight bore PTFE stopcock sampling ports. (Additional ports can be ordered.) Overall length of glass manifold is 230mm. Complete item consists of 8763…

  • Increased sensitivity and versatility over other models, mercury requirement is reduced to 20-30cc. A control point within 1mm Hg can be fine-tuned by adjusting the height of the pump-out tubulation. The Cartesian driver float drops away from pump-out orifice on an increas- ing system pressure and…

  • Borosilicate glass vacuum/NO-AIR trap. Simliar to 8755 traps but with No. 15 O-Ring side connecting joints. Ideal for vacuum cart and other vacuum or NO-AIR applications. Comes complete with stainless steel ball-joint clamp and Viton O-Ring.

  • Ace Glass

    Identical to 7531-10 with the exception that the nozzle is replaced by a sintered glass filter, porosity A (145-175 microns). Used in determination of Acrolein: 4-Hexylresorcinol Method #1. Bottle has encircling graduations from 0 to 25mL or 0 to 30mL in 5mL divisions. Inlet/ outlet are 7mm O.D.…

  • A high velocity impinger air sampling which passes 6L/min (corrected to engineering gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.035in capillary tip that is…

  • quick-ship

    Environmental Sampling Supply

    The ESS Air Sampling Bag incorporates a two opening system for sampling and extraction. The side port/stem (3/16" OD) allows filling with a pneumatic pump and tubing, and for rapid emptying of the bag. The top of the valve is

  • Permanent split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v…

  • Automatic, adjustable pressure release valve for safer operation of pilot plant or other assemblies where the pressure is of great concern. The tension on the stainless steel spring determines the amount of pressure needed to force the lower piece open. With the spring supplied, the range is 15-50…

  • Imhoff sedimentation cone for the determination of settleable matter in water. Either blunt tip or Ace-Thred tip for environmental applications. Graduated from 0-2ml in 0.1ml divisions, 2-10ml in 0.5ml divisions, 10-40ml in 1ml divisions, 40-100ml in 2ml divisions.

  • Adjustable bleed adapter used for reducing air flow in the Air Sampling Manifold to prevent a pressure drop across the sampling ports. Normally installed in front of the 7511 blower, in line with the manifold. Positioning of holes in threaded nylon plug controls the volume of air flow. Plug…

  • Falcon

    100% Ozone-safe Pure moisture-free blasts Extension tubes for precise dusting Ideal for cleaning in laboratories, photographic equipment and computers. The Special Application Formula (2905T03) has been formulated for use in especially sensitive environments, such as scientific…

Compare Tool

Select up to 3 products