Thomas No. | Item | Description |
2715B59 | Capillary Inlet Evaluation Sample (Split Mode) | Solution of 1.0% (w/w) C9, C16 in C14. Three 0.5 ml ampoules. |
2713Y06 | FID and TCD Sample | This sample is used for the HP 5880, 5890 and 6890 with a FID or TCD. Solution of 0.033% C14, C15, and C16 normal alkanes in hexane. Three 0.5 ml ampoules. |
2713Y21 | Nitrogen-Phosphorus Detector Sample | This sample is used for the HP 5880, 5890 and 6890 with a NPD. Solution of 0.65 ppm azobenzene, 1,000 ppm octadecane, and 1.00 ppm malathion in isooctane (w/v). Three 0.5 ml ampoules. |
2713Y07 | Thermal Conductivity Detector Sample | Solution of 0.33% C14, C15, and C16 normal alkanes in hexane (w/w). Three 0.5 ml ampoules. |
2713Y08 | Electron Capture Detector Sample | This sample is used for the HP 5880, 5890 and 6890 with an ECD. Solution of 33 pg/mL (0.033 ppm) (w/v) each of lindane and aldrin in isooctane. Three 0.5 ml ampoules. |
2714R75 | ECD Test Sample | Lindane, 0.033 ppm in iso-octane, 3 ampoules |
1233L81 | Flame Photometric Detector (FPD) Check Out Sample | 3 x 1 ml ampoules, Methyl Parathion in Isooctane 2.5 mg/L |
2714D61 | Flame Photometric Detector (FPD) Sample | This sample is used for the HP 5880, 5890 and 6890 with an FPD. Solution of 20 ng/µL (20 ppm) dodecanethiol and tributylphosphate in isooctane. Three 0.5 ml ampoules. |
2715B60 | Atomic Emission Detector Sample | Sample 1: Contains (w/w) 0.07% nitrobenzene, 0.43% n-tridecane, 0.07% 4-fluoroanisole, 0.05% tert-butyldisulfide, 0.08% 1,2,4-trichlorobenzene, 0.05% tetraethyl orthosilicate, 0.05% n-decane (perdeuterated), 4.3% n-dodecane, 0.13% n-tetradecane, 0.07% 1-b |
2714R36 | OQ/PV Headspace Sample | Contains 0.2-0.3% t-butyl disulfide, 1,2-dichlorobenzene, and nitrobenzene in ethanol |
2715B58 | Headspace Sample | Contains 0.2-10.0% t-butyl disulfide, 1,2-dichlorobenzene, nitrobenzene, and n-nonane in n-dodecane |
2714D67 | Nickel Catalyst Test Sample | Mixture of 10±5 ppm each of methane, carbon monoxide, and carbon dioxide in helium. One pressurized aerosol-type container (370 ml at 25 psig). |
2714L64 | Nickel catalyst refill | - |
2714D67 | MIDI System Calibration Standard | Quantitative calibration standard for the Microbial ID System. Fatty acid methyl esters w/v%. 0.01% n-C9:0, 0.02% n-C10:0, 0.01% n-C11:0, 0.02% C12:0, 0.01% C13:0, 0.02% C14:0, 0.01% n-C15:0, 0.02% n-C16:0, 0.01% n-C17:0, 0.02% n-C18:0, 0.01% n-C19:0, 0.0 |
2714L53 | Boiling Point Calibration Sample No. 1 | Mixture of the following normal hydrocarbons, approximate concentrations % weight/weight: 8.3% n-pentane, 4.4% n-hexane, 4.6% n-heptane, 4.7% octane, 4.8% nonane, 9.7% decane, 4.9% n-undecane, 19.9% n-dodecane, 10.2% n-tetradecane, 5.1% npentadecane, 10.3 |
2714L66 | Low Boiling Point Calibration Sample No 220 | Mixture of the following normal hydrocarbons, approximate concentrations % weight/weight: 8.8% n-pentane, 4.7% n-hexane, 4.8% n-heptane, 4.9% n-octane, 5.1% n-nonane, 10.3% n-decane, 5.2% n-undecane, 21.1% n-dodecane, 10.8% n-tetradecane, 5.4% npentadecan |
2714L67 | Boiling Point Calibration Sample No. 320 | Mixture of the following components, approximate concentrations % weight/weight: 6.9% n-pentane, 4.8% 2-methyl pentane, 3.6% n-hexane, 3.7% 2,4-dimethyl pentane, 3.8% n-heptane, 4.8% toluene, 3.9%n-octane, 4.8% p-xylene, 4.8% n-propyl benzene, 8.1% n-deca |
2713Y98 | Alcohol in Gasoline Sample | Test mixture containing approximately 1% each of ethanol, isopropanol, n-propanol, sec-butanol, isobutyl alcohol, tert-amyl alcohol, and n-butanol; 2% each of methanol and tert-butyl alcohol; and 3% MTBE in gasoline. Three sealed 0.5 ml ampoules. |
2714L62 | Natural Gas Sample | Approximate concentrations % volume/volume: 69% methane, 6% nitrogen, 1% carbon dioxide, 0.5% oxygen, 9% ethane, 1% npentane, 6% propane, 3% isobutane, 3% n-butane, 1% iso-pentane and 0.5% hexanes. One pressurized aerosol-type container (370 ml at 25 psig |
2714L63 | Transformer Gas Sample | Approximate composition: 0.1% each of carbon dioxide, propylene, hydrogen, carbon monoxide, propane, ethane, methane, ethylene, acetylene, butene-1, and 99% nitrogen. One pressurized aerosol-type container (16 oz/473 mL at 120 psig). |
2714L61 | Refinery Gas Sample | Approximate concentrations % volume/volume: 15% hydrogen, 5% propane, 1% propylene, 10% iso-butane, 2% iso-pentane, 1% n-pentane, 15% nitrogen, 5% methane, 5% n-butane, 10% 1-butene, 5% trans-2-butene, 5% cis-2-butene, 5% carbon dioxide, 5% carbon monoxid |
2714H26 | Reference Gas Oil No. 1 Batch 2 | Multiple component mixture of hydrocarbons from petroleum fractions. Used for performance verification of the Agilent simulated distillation analyzer, Option 840. The analyzer performs analysis of petroleum fractions according to ASTM Method D 2887. Three |