Sterilization & Biological Indicators
-
Apex® Biological Indicators
Mesa LabsApex Biological Indicators consist of stainless-steel carriers inoculated with sterilization resistant spores. Apex ribbons are inoculated on one end and flexible for easy placement.
-
Dry Heat Chemical Process Indicators (CPIs) are designed to signal, through a transition in color, when exposed to high temperatures such as dry heat and steam sterilization or depyrogenation processes. The CPIs will transition from the initial to the signal color depending on the temperature and…
-
OK® Sterilization Indicator Strips
Propper ManufacturingFor steam sterilization cycles of 250°F (121°C) and 273°F (134°C) OK® Strips are indicators that monitor all critical sterilization arameters: steam, time, and temperature. In sterilization cycles OK® Strips guard against incomplete steam penetration, presence of…
-
Crosstex manufactures Bacillus subtilis (Cell Line 5230) Spore Suspensions utilized in low temperature (<121°C) steam sterilization processes. The Spore Suspensions are pure suspensions of spores with known steam resistance characteristics and a variety of population levels standardized per…
-
VERIFY™ Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus…
-
B/T Sure™ Biological Indicators
BarnsteadVerifies the sterility of your instruments, glassware and other products in just two days Simple, three step process Run indicator through standard sterilization cycle; compress plastic vial to break glass ampule inside and then incubate for a minimum of 48 hours. When complete,…
-
Smalstrips® Steam Sterilization Monitor
Propper ManufacturingSmalstrip Sterilization Indicator Strips are an economical alternative to OK strips and are designed for monitoring steam sterilization cycles at 250°F (121°C) and 273°F (134°C). It uses the same reactive ink as the OK strip. The correct endpoint is indicated when the…
-
SporAmpule® Liquid Biological Indicators
Hardy DiagnosticsMonitoring your autoclave couldn’t be easier with the convenient SporAmpule. Easy to use! Process one or more SporAmpules, along with your normal load, then incubate at 55-60°C for 48 hours and observe for a color change. No activation, crushing, or additional culture media is…
-
Kimtech™ Kimguard™ KC600 Sterilization Wrap (68654) 54ö x 54ö 48/cs
Kimberly-Clark ProfessionalKimtech™ Kimguard™ Sterilization Wrap is a must-have tool for sterile processing environments, such as in pharmaceuticals and medical devices. The line comes in six grades of wrap fabric, from KC 100 to KC 600, so you can get precisely the right protection for your needs. The…
-
Hydrogen Peroxide Chemical Process Indicators (CPIs) are manufactured to meet performance specifications as described in ISO 11140-1 “Sterilization of health card products - Chemical indicators - Part 1: General Requirements,” for Class 1 Process Indicators. Hydrogen Peroxide CPIs are…
-
Paper Heat-Seal Sterilization Pouches
Cardinal HealthCardinal Health™ Paper Sterilization Pouch combines a blue film and a medical grade paper to provide breathability, sterile barrier, and indication of processing. Each pouch includes an external process indicator for Steam and Ethylene Oxide (EO) Gas sterilization. To assist opening, a…
-
Steam Chemical Process Indicators (CPIs) are manufactured to meet performance specifications described in ISO 11140-1 “Sterilization of health care products - Chemical indicators - Part 1: General requirements,” for Class 1 Process Indicators. The blue-to-pink color transition is…
-
-
Vapor Line® Steam Sterilization Integrators
Propper ManufacturingThe Vapor Line® integrator is a chemical indicator for monitoring the essential conditions of steam sterilization processes - saturated steam, temperature, and time in gravity displacement and pre-vacuum sterilizers operating in the 250°F - 272°F temperature range. The integrator…
-
BI-O.K.® Self-Contained Biological Indicators
Propper ManufacturingPropper BI-OK® self-contained biological indicators for Steam and EO gas are designed for sterilization efficacy monitoring in hospitals, clinics, and for industrial applications. After processing in a sterilization cycle and activation of media by crushing the glass vial, indicators need to be…
-
Nonslip Sterility Maintenance Covers
Propper ManufacturingPlastic dust covers protect the sterile pack during storage, handling, and transportation from dust, moisture, or airborne contaminants, and extend sterile shelf life when definite shelf life terms are used. Nonslip Dust covers satisfy current regulations for sterility maintenance covers.
-
Twindicator® Sterilization Indicators
Propper ManufacturingTwindicator® is an indicator designed for monitoring all critical parameters of steam sterilization cycles at 250°F (121°C) and 273°F (134°C). Twindicator® adds extra flexibility in sterilization monitoring: each 8” strip is perforated to allow for two 4” strips.…
-
Steri-Wrap® III
Propper ManufacturingA strong wrap especially suitable for heavy instrument trays Features: Efficient microbial barrier and provides for pack security Virtually lint free and has a tightly anchored fiber structure Does not delaminate and can be used on either side Excellent liquid repellency and…
-
Crosstex manufactures Bacillus subtilis (Cell Line 6633) Spore Suspensions utilized in low temperature (<121°C) steam sterilization processes. The Spore Suspensions are pure suspensions of spores with known steam resistance characteristics and a variety of population levels standardized per…
-
Steri-Wrap® I
Propper ManufacturingSuitable for all types of packaging needs Features: Efficient microbial barrier and provides for pack security Virtually lint free and has a tightly anchored fiber structure Does not delaminate and can be used on either side Excellent liquid repellency and is an effective…
-
Gas-Chex® Sterilization Indicators
Propper ManufacturingGas-Chex® Sterilization Indicator Strips have the easiest-to-remember color scheme: Red for Stop (pack was not yet processed or the process was inadequate), and Green for Go. Gas-Chex® Strips are suitable for monitoring gas concentration and exposure, and are especially suitable for…
-
Steri-Wrap® II
Propper ManufacturingA softer wrap for greater drape-ability Features: Efficient microbial barrier and provides for pack security Virtually lint free and has a tightly anchored fiber structure Does not delaminate and can be used on either side Excellent liquid repellency and is an effective…
-
3M™ Comply™ Bowie-Dick Test Packs are used to monitor the performance of vacuum-assisted 132ºC - 134ºC (270ºF - 273ºF) steam sterilizers; test packs will reproducibly detect residual air in the sterilizer chamber due to air leaks, air removal failures and inadequate…
-
BI-OK® Steam Test-Pak™
Propper ManufacturingSterilization processing of hospital goods can be tedious and error-prone. When you need the ultimate biological test for steam autoclave effectiveness, choose the BI-OK® steam test-pak™ - your guarantee of sterilization efficacy. With BI-OK® steam test-pak™ you can rest assured…
-
CSR Sterilization Wraps
CrosstexUse with EtO, steam, gamma irradiation, E-beam sterilization technology. Highest bacterial filtration efficiency (BFE) available. Highly permeable - no wet packs. Bacterial barrier to both airborne and waterborne contamination. Outstanding liquid repellency - water, alcohol, iodine. Even…
-
Dry Heat Sterility Tape
DynalonAdhesive tape for use with dry heat sterilization. Use these tapes to enhance confidence that sterilization has occurred. Color changes from white to brown. Conforms with ISO 11140/2005
-
Steam Dot® Blu™ Indicators
Propper ManufacturingSteam Dot Blu™ utilizes the latest in environmentally friendly inks: the Blu™ ink technology. All products made with Blu™ inks are free of all heavy metals, including lead. Environmentally Friendly Technology: Manufactured without lead & heavy metals …
-
Radiation Chemical Process Indicators (CPIs) are manufactured to meet performance specifications described in ANSI/AAMI/ISO 11140-1 “Sterilization of health care products - Chemical indicators - Part 1: General Requirements,” for Class 1 Process Indicators. The color transitions are…
-
Sure-Check® Sterilization Pouches
CrosstexSure-Check Pouches with built-in internal/external multi-parameter steam sterilization indicators confirm all sterilization criteria—time, temperature and presence of steam. Until now, due to limitations in technology, sterilization pouches have had only single parameter chemical…
-
Kimtech™ Kimguard™ KC100 Sterilization Wrap
Kimberly-Clark ProfessionalKimtech™ Pure Kimguard Sterilization Wrap is a must-have tool for sterile processing environments, such as in pharmaceuticals and medical devices. The line comes in six grades of wrap fabric, from KC 100 to KC 600, so you can get precisely the right protection for your needs. The higher the…
-
Mini Self-Contained Biological Indicators (SCBIs) for Monitoring Steam Sterilization Processes, Geobacillus stearothermophilus Cell Line 7953, SCBIs each 8.4 mm x 45.5 mm, 10 5 population level, 25 per box, ISO 11138-1, 11138-3 and USP compliant where applicable.
-
Chex-All® III Pouches
Propper ManufacturingProcess indicators are printed on the pouch corners and covered by the extension of the transparent film beyond the sealed area. This guarantees protection of the indicators from direct contact with metal trays or instruments, yet does not obstruct observation of the indicator color change. …