HPLC Instrument Parts and Supplies Products (0)

Compare Tool

Select up to 3 products

  • > Next
  • Thumbnail Image for EZwaste® Solvent Waste System

    Foxx Life Sciences

    EZ-Waste Solvent Waste System is designed to be an affordable solution for liquid waste disposal.Carbon exhaust filter traps solvent vapors,tube fittings secure waste tubes to carboy, providing the closes system necessary to prevent spills. 90° adapter included for maximum storage flexibility....

  • Thumbnail Image for Solvent Inlet Filters

    Thermo Scientific

    For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit

  • Thumbnail Image for Opti-Cap GL-45 Bottle Tops

    Restek

    The most economical way to helium-sparge and deliver LC mobile phases. Opti-Cap tops fit all standard GL-45 bottles and have two 1/8" holes and one 1/16" hole for tubing. All three openings are designed for threaded PEEK plugs.

  • Thumbnail Image for Diode Array Detector (DAD)/Multiple Wavelength Detector (MWD)

    Agilent Technologies

    Agilent's certified lamps are manufactured under ISO 9001 certified environment and are fully traceable through out every step of the production process. Each lamp is then tested to ensure it meets Agilent's specifications for performance. Test equipment is regularly calibrated using optical...

  • Thumbnail Image for Purge Valve

    Agilent Technologies

    Common to all 1100/1200 pump modules, the purge valve has a gold seal held in place with a plastic cup The most frequently replaced item in the 1100/1200 Series pumps is the purge valve PTFE frit, which can clog with seal material or solvent particulates When replacing the frit, remember...

  • Thumbnail Image for Upchurch PEEK Fingertight Fitting nut and ferrule 10-32

    MilliporeSigma

    Material: PEEK nut and ferrule Packaging: pkg of 10 ea I.D.:  0.0625 in. (1.5875 mm) Fitting:  nut and ferrule 10-32 General description The one-piece fitting, 55067-U, is convenient to use because the ferrule will not stick in a receiving port and can be easliy found if dropped onto the...

  • Thumbnail Image for Eco-Cap Bottle Top, ETFE

    Restek

    Fits all standard GL-45 bottles; has two 1/8-inch holes and one 1/16-inch hole for tubing. Holes are not threaded.

  • Thumbnail Image for 1100/1200 Needles and Needle Seats

    Agilent Technologies

    The needle should be replaced when it becomes bent, burred or blunt. The needle seat should be replaced when it is leaking or plugged. You should suspect a leak if you notice a trail of buffer crystals on the needle seat. The needle seat can become blocked if the sample contains particulates, as...

  • Thumbnail Image for Solvent Filters for G1311/12/54A Pumps

    Agilent Technologies

    Unfiltered solvents or solvents contaminated with microbial growth can clog solvent inlet filters, reducing the lifetime of the filter and impacting pump performance. Remember to clean or replace the solvent inlet filters at least once every 3 months.

  • Thumbnail Image for LC Stainless Steel Capillary Tubing

    Restek

    Whether you need to replace system tubing as part of your troubleshooting or want to reduce the dwell volume of your system as you move to narrower columns, Restek has the quality tubing in the lengths and IDs you need. Each ID is color coded, so it is easy to identify and replace correctly. Tubing...

  • Thumbnail Image for LC Fittings and Unions

    Agilent Technologies

    Different columns have different fitting requirements. (Zorbax columns use standard Swagelok fittings) Agilent 1100 modules use standard Swagelok fittings Rheodyne injection valves require Rheodyne fittings How do you choose the correct fittings? To ensure leak-free connections, and to prevent the...

  • Thumbnail Image for MSD Electron Multipliers and Replacement Horn

    Agilent Technologies

    These are the recommended replacement multipliers and horns for the MSD. Other manufacturers’ products may be incompatible with Agilent instruments and can result in reduced sensitivity, lifetime, and noise problems. The electron multiplier replacement horn (2713M88) is for use with 5975,...

  • Thumbnail Image for ProteCol® Unions

    SGE

    Precision engineered for Capillary LC, ProteCol Unions offer complete versatility for connecting a range of capillary tubing. Manufactured to exacting tolerances and available in PEEK and stainless steel, the zero dead volume design provides faultless butt connections.

  • Thumbnail Image for Autosampler Supplies

    Agilent Technologies
  • Thumbnail Image for Inert PEEK Tubing

    Restek

    Replaces stainless steel, titanium, PTFE, or Tefzel tubing Less oxygen permeable and more temperature resistant (to 100 °C) than PTFE or Tefzel tubing Use with PEEK finger-tight or flangeless fittings Use tubing ≤ 0.007" to 7,000 psi; tubing ≥ 0.010" ID to 5,000 psi

  • Thumbnail Image for PEEKsil Capillary Tubing

    Thermo Scientific
  • > Next

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.